ITP Printing Totalisor

The ITP is an device where the counting and printing functions have been combined into the one instrument, when mounted on a tanker it is a more effecient use of space. The high contrast 1 line x 8 character LED display is easily read in all light conditions, is comined with an impact matrix printer to create an excellent product.

FEATURES

  • Totalise with field programmable K factors
  • Print with time and date stamp, client name, truck number and job number
  • Background accumulated total
  • 10 years memory retention in power down
  • Low cost - High performance
  • High contrast 1 line x 8 character LED display
  • Impact dot matrix printer
  • Panel mounting
  • Isolated 24VDC sensor supply
  • Applications include totalising flow with printed receipt of load delivered
  • Screw terminal electrical connection
  • 85-265VAC 47-63 Hz VAC or 10-40 VDC supply
  • Emc compliant

TECHNICAL SPECIFICATIONS

Input Details
The instrument counts input pulses at up to 5Khz and displays the totalised value and prints the value on command. The input signal is dip switch selectable for a dry relay contact, open collector transistor, reed switch, hall effect switch or turbine flow meter.

Output Details
Two output relays are provided with form C contacts rated at 5 amps 240VAC resistive. 

Display
The ITP incorporates a 1 line x 8 character of 14mm digit height high contrast LED alphanumeric display.

Scaling Factor
This is the pulses per unit of measure. It is programmable from the front panel.

Totaliser Memory
The instrument incorporates a running and a background total. In normal operation the reset button will only reset the running total.

Printer
This is a 40 character per line impact dot matrix printer. It will print the user name, total, back ground total, time, date and signature. The front of the printer is hinged to allow it to swing open for the replacement of the paper roll.

Environmental Parameters
  • 0-70 degrees Celsius
  • 0-90% Rh non-condensing
Connection Details
Terminal 1:Input 0VDC   
Terminal 11:not used
Terminal 2:Count in minus (-)
Terminal 12:Relay 1 N.C. contact
Terminal 3:Count in plus (+)
Terminal 13:Relay1 N.O. contact
Terminal 4:not used
Terminal 14:Relay 1 common contact
Terminal 5: not used
Terminal 15:not used
Terminal 6:Initialise print
Terminal 16:not used
Terminal 7:Reset
Terminal 17:not used
Terminal 8:24VDC LP supply
Terminal 18:VAC/VDC active supply
Terminal 9: pulse per litre output
Terminal 19:VAC neutral/0VDC supply
Terminal 10:not used
Terminal 20:Ground supply

Instrument Power Supply
85-265VAC power supply 47-63 Hz or factory fitted DC to DC converter isolator from 12 to 40VDC.

Transducer Power Supply
24VDC @ 50mA transducer power supply is included in the instrument.

Weight
1800 grams.

Mounting Details
Panel mounting aluminium enclosure of case dimensions 144mm wide x 144 mm high x 145 mm deep with a panel cut out of 138 mm wide by 138 mm high.

Ordering Information
  • Model/input signal/display units/power supply/options
  • Sample number: ITP/CC24/0-999999/VAC/1.000
  • All units shipped factory calibrated to a scaling factor of 1.0 unless specified